The DragLab Incubator Series is supplied with the essential components required for installation and routine laboratory use. The standard package includes:
- Incubator unit
- Power cable
- Two chrome-plated wire shelves
- Operating manual
- Service manual
Depending on the model, application, or customer requirements, optional accessories may also be available, including:
- Additional wire shelves (wire racks)
- Calibration certificate
- Language packages for documentation
For information about model-specific accessories or optional equipment, please contact your local DragLab distributor or authorized representative
Yes. DragLab Water Still systems are designed for continuous day-to-day laboratory use, delivering a dependable supply of distilled water for routine applications. Their durable stainless-steel construction, automatic operation, and integrated safety features ensure reliable performance with minimal operator intervention. Whether used in research laboratories, universities, hospitals, or industrial quality control facilities, the systems are built to provide consistent water production throughout the working day.
Installing a DragLab Water Still is quick and straightforward. All standard accessories required for operation are supplied with the unit. To begin operation, the system only requires a suitable electrical supply (220 V or 400 V, depending on the model), a continuous feed water connection, and a drain for wastewater. Once these utilities are available, the unit can be installed easily by following the instructions in the user manual.
Yes. All DragLab Water Still models can be installed on a laboratory bench, providing convenient access for routine operation and maintenance. In addition, selected models—including the DS 2000, DS 4000, and DS 8000—also support wall-mounted installation, making them an excellent choice for laboratories where bench space is limited.
All models in the DragLab Drying Oven Series, including both the Digital Display (DO Series) and Touch Screen (TO Series), are supplied with two chrome-plated steel shelves as standard, providing immediate flexibility for a wide range of laboratory heating and drying applications.
Depending on the selected model, additional shelf positions are available to maximize chamber capacity and improve batch throughput:
|
Model |
Standard Shelves |
Maximum Shelf Positions |
|
DO 30 / TO 30 |
2 |
5 |
|
DO 55 / TO 55 |
2 |
8 |
|
DO 80 / TO 80 |
2 |
10 |
|
DO 120 / TO 120 |
2 |
11 |
The ability to accommodate multiple shelf positions allows laboratories to process larger batches in a single heating cycle, improving productivity and making efficient use of the available chamber space. Each shelf is designed to support laboratory samples, glassware, and other compatible materials while maintaining adequate airflow throughout the chamber for consistent heating performance.
Yes. The DragLab Incubator Series is designed for straightforward installation in laboratory environments. After placing the incubator on a stable laboratory workbench with the recommended installation clearances, simply connect it to the appropriate 230 V, 50/60 Hz electrical supply before operation.
For optimum performance, the incubator should be installed in a clean, dry, and well-ventilated location while maintaining the recommended clearance of 15 cm from the rear wall, at least 5 cm from each side, and 20 cm above the unit. Once installed, users can configure the desired temperature and timer settings through the digital display (DI Series) or touch screen interface (TI Series), allowing the incubator to be ready for routine laboratory use.
Yes. A continuous feed water supply is essential for uninterrupted distilled water production. During operation, fresh feed water continuously enters the boiling chamber while distilled water is produced and collected. Maintaining a stable water supply helps ensure consistent performance, protects the heating system, and allows the automatic safety features to operate correctly for reliable day-to-day laboratory use.
The DragLab Drying Oven Series is designed to operate on a 230 V AC, 50/60 Hz single-phase power supply, making it suitable for standard laboratory electrical installations in many regions. Before installation and initial operation, users should verify that the available mains supply matches the voltage and frequency specified on the equipment nameplate.
For safe and reliable operation, the oven should be connected to a properly grounded electrical outlet that complies with local electrical regulations. Using the correct power supply helps ensure stable heating performance, accurate temperature control, and the reliable operation of the programmable PID controller and other electrical components.
Before connecting the oven to the mains, users should also inspect the power cable for any signs of damage and ensure that the electrical installation is capable of supporting the power requirements of the selected model. Following these recommendations helps protect both the equipment and laboratory personnel while ensuring optimum performance throughout the oven's service life.
The DragLab Incubator Series should be installed on a stable, level laboratory surface in a clean, dry, and well-ventilated environment. To ensure proper airflow and cooling performance, maintain the recommended installation clearances around the unit and operate it within the specified ambient conditions.
Yes, selected models of the DragLab Incubator Series are designed for benchtop installation.
The 30 L, 55 L, and 80 L models (DI30/TI30, DI55/TI55, and DI80/TI80) can be installed on a stable laboratory bench capable of safely supporting the incubator and its maximum operating load.
The 120 L models (DI120/TI120) are not intended for benchtop installation due to their larger size and weight. They should be installed on a suitable floor-standing surface that meets the installation requirements specified in the operating manual.
For all models, adequate clearance should be maintained around the incubator to ensure proper ventilation and safe operation.
The DragLab Incubator Series operates on a 230 V, 50/60 Hz electrical supply with a rated power of 1500 W. Before installation, ensure that the laboratory power supply matches the electrical specifications of the selected model.
Yes. DragLab Water Still systems are equipped with automatic operating features that simplify daily laboratory use and reduce the need for constant operator supervision. Automatic water level control and integrated safety protection help maintain continuous distilled water production while protecting the system during operation. This enables reliable, efficient, and user-friendly performance for routine laboratory applications.
The DragLab Incubator Series is designed to operate in laboratory environments with an ambient temperature of +5°C to +55°C and a maximum relative humidity of 80% RH. Operating the incubator within these recommended environmental conditions helps ensure stable temperature control, reliable performance, and consistent incubation results.
For the best performance, the incubator should be installed in a clean, dry, and well-ventilated location away from direct sunlight, excessive heat sources, or areas subject to rapid temperature fluctuations. Maintaining the recommended ambient conditions also supports the efficiency of the forced-air circulation system and the programmable PID controller, helping the incubator maintain homogeneous temperature distribution throughout the chamber.
For proper ventilation, the DragLab Incubator Series should be installed with the following minimum clearances:
- Rear: at least 15 cm
- Each side: at least 5 cm
- Above the unit: at least 20 cm
Maintaining these clearances allows adequate airflow and supports reliable operation.
Yes. The DragLab Incubator Series requires adequate ventilation around the unit. During installation, the recommended minimum clearances should be maintained to ensure sufficient airflow. The incubator also features forced-air circulation by a quiet, automatically adjustable air turbine, which helps maintain uniform temperature distribution inside the chamber.
The DragLab Water Bath Series should be installed on a stable, level, and heat-resistant laboratory bench capable of safely supporting the weight of the water bath when fully filled with water and samples. Proper installation helps ensure safe operation, accurate temperature control, and long-term equipment reliability.
The installation area should be clean, dry, well ventilated, and protected from direct sunlight, excessive dust, corrosive chemicals, and strong vibrations. To prevent overheating and allow sufficient air circulation, adequate clearance should be maintained around the unit, and the ventilation openings should never be obstructed.
For safe operation, the electrical supply must match the voltage and frequency specified on the equipment nameplate, and the power outlet should be properly grounded. The water bath should always be positioned where the drain valve remains easily accessible for routine water replacement and maintenance.
Before installing the DragLab Drying Oven Series, the oven should be placed on a stable, level, and heat-resistant surface in a clean, dry, and well-ventilated laboratory environment. Adequate clearance should be maintained around the unit to ensure proper air circulation, efficient heat dissipation, and easy access for routine operation and maintenance.
Before connecting the oven to the mains supply, users should verify that the voltage and frequency of the electrical supply match the values specified on the equipment nameplate and that the unit is connected to a properly grounded electrical outlet. It is also recommended to install the oven away from direct sunlight, sources of excessive heat or moisture, and areas containing flammable or explosive materials to ensure safe, reliable, and long-term operation.
Yes. All models in the DragLab Water Bath Series (DW 06, DW 10, DW 15, DW 25, DW 35, and DW 50) are designed as bench-top laboratory water baths. They should be placed on a strong, level, and stable laboratory bench capable of supporting the combined weight of the unit, the water, and the maximum sample load during operation.
Because larger-capacity models contain significantly more water, laboratories should verify that the supporting surface is suitable for the fully loaded operating weight. Installing the unit on a stable bench also helps minimize vibration, maintain proper water circulation, and ensure consistent temperature performance.
The bench should allow sufficient space around the appliance for ventilation, routine cleaning, and convenient access to the control panel and drain valve.
The DragLab Water Bath Series is designed to operate from a 230 V, 50/60 Hz single-phase power supply. Before installation, users should verify that the laboratory mains supply matches the voltage and frequency specified on the equipment nameplate and that the outlet is properly grounded.
All models in the series—DW 06, DW 10, DW 15, DW 25, DW 35, and DW 50—operate on 230 V, 50/60 Hz with a rated power of 1000 W, according to the current product specifications.
For safe and reliable operation, the water bath should be connected to a dedicated, properly grounded electrical outlet protected by an appropriate circuit. The use of overloaded power outlets or extension cords should be avoided whenever possible. In addition, the power cable should remain easily accessible so that the unit can be disconnected quickly in the event of an emergency or during routine maintenance.
To ensure proper ventilation, efficient heat dissipation, and reliable long-term performance, DragLab recommends maintaining the following minimum installation clearances around the oven:
· Rear: 15 cm (5.9 in)
· Left and right sides: 5 cm (2.0 in) each
· Top: 20 cm (7.9 in)
Maintaining these minimum clearances allows unrestricted airflow around the oven, helping to prevent excessive heat buildup and ensuring stable operating conditions. Adequate spacing also provides convenient access for routine inspection, cleaning, and maintenance while contributing to the safe and efficient operation of the equipment.
Setting the incubation temperature on the DragLab Incubator Series is simple and intuitive. After switching on the incubator, access the temperature setpoint from the main operating screen by selecting the Set Temperature field. Enter the desired incubation temperature using the on-screen numeric keypad and confirm the value by pressing Enter.
Once the incubation cycle is started, the programmable PID microprocessor controller automatically heats the chamber until the selected setpoint is reached and continuously regulates the temperature to maintain stable incubation conditions. Users can also view both the actual chamber temperature and the programmed set temperature at any time from the temperature display screen, allowing easy monitoring throughout the incubation process.
On DI Series models, temperature settings are entered using the digital controller, while TI Series models (TI 30, TI 55, TI 80, and TI 120) provide an intuitive touch-screen interface for quick and convenient temperature adjustment. Always ensure that the selected temperature is within the operating range of the DragLab Incubator Series before starting the incubation cycle.
Distilled water is recommended for normal operation of the DragLab Water Bath Series. Distilled water minimizes mineral deposits, helps maintain efficient heat transfer, and reduces the formation of limescale on the heating element and stainless-steel chamber.
Tap water is generally not recommended because dissolved minerals such as calcium and magnesium can gradually form scale deposits that reduce heating efficiency, create localized hot spots, and increase maintenance requirements.
Highly purified deionized or ultrapure water may also be unsuitable for long-term use because, depending on its purity and chemistry, it can be more aggressive toward certain metallic components. For most laboratory applications, distilled water provides the best balance between equipment protection and reliable operating performance.
Using clean water and replacing it regularly helps maintain stable temperature performance, reduces contamination, and extends the service life of the water bath.
Yes. Most models in the DragLab Drying Oven Series are designed for bench-top laboratory installation when placed on a stable, level, and heat-resistant surface capable of supporting the oven and its maximum operating load. The DO 30 / TO 30, DO 55 / TO 55, and DO 80 / TO 80 models are suitable for installation on standard laboratory benches, making them ideal for laboratories with limited space.
The larger DO 120 / TO 120 models are intended as floor-standing units due to their larger chamber capacity and overall dimensions. Regardless of the model, users should maintain the recommended installation clearances to ensure adequate ventilation, proper heat dissipation, and safe, reliable operation. Proper installation also helps maintain consistent heating performance and provides convenient access for routine operation and maintenance.
For reliable performance, the DragLab Drying Oven Series should be operated in an environment with:
- Ambient temperature: +5°C to +55°C
- Relative humidity: Maximum 80% RH
Operating outside these conditions may affect performance and equipment reliability.
The water level should always be maintained above the heating element to ensure safe operation and efficient heat transfer. As a general guideline, the bath should be filled up to the internal step (ledge) formed by the change in the shape of the chamber, which serves as the recommended maximum filling level.
If the water level is too low, the heating element may not be fully covered, reducing heating performance and activating the low-water protection system. Overfilling the bath should also be avoided, as the water level will rise when sample containers are placed into the bath and may result in overflow.
During extended operation, particularly at elevated temperatures, users should periodically check the water level and replenish the bath with distilled water as needed to compensate for evaporation. Maintaining the correct water level helps ensure stable temperature control, efficient heating, and reliable long-term operation.
Yes. The DragLab Water Bath Series is designed to support continuous laboratory operation when used in accordance with the operating manual and established laboratory safety procedures.
The digital temperature controller continuously regulates the water temperature, while the integrated circulation pump maintains uniform heat distribution throughout the bath. Safety features, including over-temperature protection and low-water protection, help support reliable long-term operation.
Before leaving the water bath operating unattended, users should verify that the bath contains sufficient water, the correct operating temperature has been selected, the lid is properly positioned to reduce evaporation, and no hazardous or incompatible materials are being heated.
After a power interruption, the operating behavior depends on the controller configuration and the duration of the outage. Users should always verify the displayed temperature setting and operating status after power has been restored before resuming laboratory work.
For critical laboratory procedures, DragLab recommends confirming that the bath has returned to the required operating temperature and has reached thermal equilibrium before continuing temperature-sensitive applications.
Where uninterrupted temperature control is essential, laboratories may consider using an appropriate uninterruptible power supply (UPS) or backup power system.
Yes, the DragLab Water Bath Series can operate without the lid when required by certain laboratory procedures. However, using the supplied stainless-steel lid is strongly recommended during normal operation.
The lid helps reduce water evaporation, improves temperature stability, shortens heat-up time, minimizes heat loss, and helps reduce the risk of contamination from airborne particles entering the bath. These benefits become particularly important during prolonged heating cycles or when operating at higher temperatures.
For the best thermal performance and water conservation, DragLab recommends keeping the lid in place whenever practical during routine laboratory operation.
The DragLab Drying Oven Series is supplied with the essential components required for installation and normal laboratory operation. The standard package typically includes:
· DragLab Drying Oven (selected model)
· Power cable
· Two chrome-plated steel shelves
· Operating manual
· Service manual
Depending on the model, configuration, or customer requirements, a range of optional accessories may also be available to enhance functionality and accommodate different laboratory applications. These may include:
· Additional chrome-plated steel shelves
· Shelf support rails
· Replacement door gasket
· Replacement temperature sensor
· Spare fuses
· Calibration and validation services (where available)
· Other genuine DragLab spare parts and accessories
The supplied accessories and optional components may vary according to the selected model, regional requirements, or customer specifications. Using genuine DragLab accessories and replacement parts helps ensure optimum performance, reliable operation, and long-term equipment durability.
To minimize downtime and support routine maintenance, it is recommended to keep commonly used spare parts in stock. Depending on the model and operating conditions, these may include heating elements, seals, tubing, the pre-filter cartridge if applicable. Keeping these spare parts readily available helps ensure reliable operation, reduces maintenance time, and extends the service life of your DragLab Water Still. For model-specific spare parts recommendations, please contact your local DragLab distributor or sales representative.
The DragLab Water Still Series is supplied with the essential components required for installation and operation. The standard package typically includes:
- Water still unit
- Power supply cable
- Distillate faucet
- Water inlet hose with connector
- Silicone tubing
- Operating manual
Depending on the model, configuration, or customer requirements, optional accessories may also be available, including:
- Wall-mounting bracket (for compatible models)
- Replacement pre-filter cartridge
- Spare silicone tubing
- Additional hose connectors and fittings
- Spare heating element
- Spare gasket and sealing kit
Package contents and optional accessories may vary by model and destination country. Please refer to the product documentation or contact your local DragLab distributor for specific details.
Check the spelling, try a different term or choose another category above. Or ask us directly: +49 6196 400816, info@drag-lab.de.
Planning a purchase?
Send us your request. We will prepare a quote and help you choose the right device.