The DragLab Water Bath Series is a range of laboratory stirred water baths designed to provide accurate, stable, and uniform temperature control for a wide variety of laboratory applications. The series is suitable for gently heating, warming, incubating, thawing, and maintaining samples at controlled temperatures without exposing them to direct heat.
Unlike dry heating methods, water acts as an efficient heat-transfer medium, providing gentle and homogeneous heating around the entire sample. This makes the Water Bath Series particularly suitable for temperature-sensitive materials and applications requiring stable thermal conditions.
Every DragLab Water Bath is equipped with an integrated circulation pump that continuously moves the water throughout the tank, minimizing temperature gradients, improving heat distribution, and providing faster temperature recovery after samples are introduced. The baths are constructed with a durable stainless-steel chamber, feature digital temperature control, and include a drain valve for convenient water replacement and routine maintenance.
The DragLab Water Bath Series is widely used in research laboratories, pharmaceutical laboratories, clinical and diagnostic laboratories, microbiology, biotechnology, food and beverage testing, environmental analysis, universities, industrial laboratories, and quality control applications.
The DragLab Drying Oven Series is a high-performance laboratory heating oven designed for precise drying, heating, curing, conditioning, and thermal processing of non-flammable materials. Equipped with a programmable PID microprocessor controller and an efficient forced-air circulation system, the oven delivers accurate temperature control and excellent temperature uniformity throughout the chamber for reliable and reproducible results.
Constructed with a durable AISI 304 stainless steel chamber, the series is designed for long-term laboratory use while offering easy cleaning and corrosion resistance. Available in multiple chamber sizes, the DragLab Drying Oven Series is suitable for a wide range of applications, including sample drying, glassware drying, material testing, quality control, research, industrial laboratories, universities, and pharmaceutical facilities. Its combination of reliable performance, user-friendly operation, and comprehensive safety features makes it an ideal solution for laboratories requiring consistent and dependable thermal processing.
The DragLab Water Still Series is a range of laboratory water distillation systems designed to produce high-quality distilled water for research, clinical, educational, pharmaceutical, and industrial laboratories. The series includes multiple models such as (DS 2000, DS 4000, DS 8000, DS 8008, DS 8012 and DS 8025) with different production capacities to meet various laboratory requirements.
The DragLab Incubator Series is a range of high-performance laboratory incubators designed to provide precise, reliable, and homogeneous temperature control for routine incubation applications. Available with either a digital display (DI Series) or an intuitive touch screen interface (TI Series), the incubators feature programmable PID temperature control, forced-air circulation, and chamber capacities ranging from 30 to 120 liters.
Designed for consistent and reproducible incubation conditions, the DragLab Incubator Series is suitable for a wide range of laboratory applications, including microbiology, biotechnology, pharmaceutical research, quality control, food testing, and general scientific research. Its durable AISI 304 stainless steel chamber, user-friendly controls, and uniform temperature distribution make it an ideal solution for laboratories requiring dependable day-to-day performance.
DragLab Water Still systems purify water through a single distillation process. Feed water is heated in a stainless-steel boiling chamber until it turns into steam. The steam then passes through an efficient condenser, where it cools and condenses into high-quality distilled water. During this process, most dissolved salts, minerals, microorganisms, and other contaminants remain in the boiling chamber and are separated from the purified water. This simple and reliable process enables DragLab Water Still systems to consistently produce distilled water suitable for a wide range of laboratory applications.
The DragLab Drying Oven Series is available in two controller configurations to meet different laboratory preferences and operational requirements: Digital Display (DO Series) and Touch Screen (TO Series). Both series offer identical heating performance, temperature range, and chamber construction, differing primarily in the user interface and control method.
Digital Display Models (DO Series):
· DO 30 – 30 L
· DO 55 – 55 L
· DO 80 – 80 L
· DO 120 – 120 L
Touch Screen Models (TO Series):
· TO 30 – 30 L
· TO 55 – 55 L
· TO 80 – 80 L
· TO 120 – 120 L
All models feature a durable AISI 304 stainless steel chamber, programmable PID temperature control, and forced-air circulation to ensure accurate temperature regulation and excellent temperature uniformity. With chamber capacities ranging from 30 to 120 liters, the DragLab Drying Oven Series offers a suitable solution for a wide variety of laboratory drying, heating, conditioning, and thermal processing applications.
The DragLab Incubator Series is suitable for a wide range of laboratory applications, including clinical microbiology, biotechnology, cell culture, media preparation, microbiology and bacteriology sample preparation, pharmaceutical manufacturing, food and beverage production, cosmetics, material testing, and general research laboratories.
The DragLab Incubator Series is available in four chamber capacities—30 L, 55 L, 80 L, and 120 L—with a choice of either a Digital Display (DI Series) or a Touch Screen (TI Series) interface. The available models are:
- DI 30 / TI 30 (30 L) – Compact incubators ideal for laboratories with limited bench space, educational laboratories, and routine microbiology or low-volume sample incubation.
- DI 55 / TI 55 (55 L) – Versatile models designed for everyday laboratory use, offering an excellent balance between chamber capacity and footprint for general research and quality control applications.
- DI 80 / TI 80 (80 L) – Suitable for laboratories processing larger sample volumes or running multiple incubation projects simultaneously while maintaining efficient use of laboratory space.
- DI 120 / TI 120 (120 L) – The largest incubators in the series, designed for high-throughput laboratories, pharmaceutical and industrial quality control laboratories, and research facilities requiring maximum incubation capacity.
All models feature programmable PID temperature control, forced-air circulation, an AISI 304 stainless steel chamber, and homogeneous temperature distribution. The primary difference between the DI and TI series is the user interface: DI models feature a reliable digital display for straightforward operation, while TI models offer an intuitive touch screen for easier programming and enhanced user convenience.
Choosing the right model depends on your available laboratory space, the number and size of samples you process, and your preferred control interface, while all DragLab incubators provide the same dependable incubation performance.
The DragLab Drying Oven Series operates from ambient temperature +5°C up to +300°C, making it suitable for a wide variety of laboratory heating and drying applications requiring elevated temperatures.
The DragLab Water Still Series is designed to produce high-quality distilled water for a wide range of laboratory applications. It is ideal for reagent and media preparation, glassware rinsing, microbiology and analytical testing, instrument feeding, and sample preparation. The series is widely used in research laboratories, universities, hospitals, pharmaceutical and biotechnology facilities, environmental laboratories, and industrial quality control laboratories where a reliable supply of distilled water is essential.
The DragLab Water Bath Series consists of six models designed to accommodate different laboratory capacities while maintaining the same operating principles, temperature control system, and user-friendly operation.
The available models are:
- DW 06 – 6 L
- DW 10 – 10 L
- DW 15 – 15 L
- DW 25 – 25 L
- DW 35 – 35 L
- DW 50 – 50 L
All models feature a stainless-steel bath chamber, digital temperature controller, integrated water circulation pump, stainless-steel lid, drain valve, and over-temperature safety protection. Larger models provide increased working capacity for higher sample throughput while preserving the same reliable heating performance across the product range.
This broad range allows laboratories to select the most suitable capacity for routine sample preparation, research, educational use, pharmaceutical testing, industrial laboratories, and quality control applications.
The DragLab Incubator Series is available with useful chamber volumes of 30 L, 55 L, 80 L, and 120 L, allowing laboratories to select the most suitable capacity for their application and sample workload.
Selecting the appropriate model depends primarily on the size and number of vessels that need to be heated simultaneously rather than simply choosing the largest tank available. The bath should provide sufficient working space while allowing water to circulate freely around all containers to maintain uniform temperature distribution.
As a general guide:
- DW 06 and DW 10 are ideal for routine laboratory work, educational laboratories, and small batches of test tubes or sample containers.
- DW 15 and DW 25 are well suited for research laboratories, microbiology laboratories, pharmaceutical quality control, and medium-volume daily applications.
- DW 35 and DW 50 are recommended for larger vessels, higher sample throughput, industrial laboratories, and applications requiring continuous operation with greater working capacity.
When selecting a model, laboratories should also consider the available bench space, the dimensions of the containers being used, future workload requirements, and the need to maintain adequate water circulation around every sample. Choosing the correct capacity helps maximize temperature uniformity, heating efficiency, and overall laboratory productivity.
The DragLab Water Still Series is suitable for a wide range of laboratories requiring a reliable supply of distilled water. It is commonly used in universities, research institutes, hospitals, pharmaceutical and biotechnology laboratories, food and beverage testing laboratories, environmental laboratories, and industrial quality control facilities. With multiple production capacities available, the series can support the needs of both small research laboratories and large centralized laboratory operations.
The DragLab Drying Oven Series is equipped with a programmable PID microprocessor controller, providing accurate temperature regulation, stable operation, and repeatable heating performance throughout the working cycle.
The DragLab Incubator Series provides a temperature range from ambient +20°C up to 100°C, making it suitable for a wide variety of routine laboratory incubation applications. This range covers the temperature requirements for microbiology, cell culture, biotechnology, pharmaceutical research, food testing, and quality control laboratories.
To ensure reliable and reproducible results, the incubators are equipped with a programmable adaptive PID microprocessor controller and a forced-air circulation system that work together to maintain stable and homogeneous temperature conditions throughout the chamber. This combination helps minimize temperature variations and ensures consistent incubation performance, even when the chamber is fully loaded.
The temperature range is the same across all DI 30, DI 55, DI 80, DI 120 and TI 30, TI 55, TI 80, TI 120 models, allowing users to select the appropriate chamber capacity without compromising temperature performance.
The key difference between a circulating water bath and a static water bath is the movement of the water inside the chamber. A static water bath relies mainly on natural convection to distribute heat, while a stirred water bath continuously circulates the water using an integrated pump.
Continuous circulation provides several important advantages:
- More uniform temperature throughout the entire bath
- Faster heat transfer to samples
- Reduced temperature gradients and cold spots
- Faster temperature recovery after introducing cold samples
- Improved consistency when multiple vessels are heated simultaneously
- Better performance in larger-capacity water baths
Unlike many laboratory water baths where circulation is available only as an optional feature, every model in the DragLab Water Bath Series is equipped with an integrated circulation pump as standard equipment. This ensures consistent heating performance across the entire product range without requiring optional upgrades, making the series suitable for laboratories that require reliable and repeatable temperature-controlled applications.
Tap water contains dissolved minerals, salts, microorganisms, and other impurities that may affect experimental accuracy, contaminate samples, or cause scale buildup in laboratory equipment. DragLab Water Still systems produce high-quality distilled water with a typical conductivity of approximately 2.3 µS/cm at 25°C, providing a reliable water source for routine laboratory applications. By using distilled water, laboratories can improve the consistency of test results, reduce contamination risks, protect sensitive instruments, and extend the service life of laboratory equipment.
According to the product specifications, the DragLab Drying Oven Series provides a temperature accuracy of ±0.1°C, ensuring precise and reliable temperature control for a wide range of laboratory heating applications. This high level of accuracy helps maintain stable operating conditions, supporting repeatable results in drying, conditioning, curing, material testing, and other temperature-sensitive laboratory procedures.
The DragLab Incubator Series combines forced-air circulation, programmable PID temperature control, homogeneous temperature distribution compliant with DIN 12880, and durable AISI 304 stainless steel chambers to deliver reliable incubation performance. Available with either a digital display or touch screen interface, the series is designed for accurate temperature control, user-friendly operation, and dependable performance across a wide range of laboratory applications.
DragLab Water Still systems are designed to produce high-quality distilled water with a typical conductivity of approximately 2.3 µS/cm at 25°C, making it suitable for a wide range of laboratory applications, including reagent preparation, glassware rinsing, media preparation, and general laboratory use. The final water quality may vary depending on feed water quality, operating conditions, and proper system maintenance.
Yes. The DragLab Drying Oven Series is equipped with an automatically adjustable forced-air circulation system that continuously circulates heated air throughout the chamber to promote uniform temperature distribution and consistent heating performance. This efficient airflow helps minimize temperature variations, improves heat transfer, and supports reliable drying and heating results across different shelf levels.
The DragLab Incubator Series is used across a broad range of industries, including biotechnology, pharmaceuticals, human diagnostics, food and beverage production, chemical laboratories, cosmetics manufacturing, medical research, water analysis, and research institutions requiring controlled incubation conditions.
Yes. The quality of the feed water can affect the efficiency, maintenance frequency, and long-term performance of DragLab Water Still systems. Hard water with high mineral content may lead to faster scale buildup inside the boiling chamber and heating element, increasing the need for periodic cleaning and descaling. Following the recommended maintenance schedule and using clean feed water whenever possible helps ensure consistent distilled water quality, reliable operation, and a longer service life.
The DragLab Water Bath Series is designed to operate from approximately 5°C above ambient temperature up to 100°C. Because the bath is heated but not refrigerated, the minimum achievable operating temperature depends on the surrounding laboratory environment. For example, in a laboratory with an ambient temperature of 25°C, the lowest practical operating temperature is approximately 30°C.
The upper temperature limit of 100°C allows the water bath to support a wide variety of laboratory heating applications, including sample warming, reagent preparation, incubation, enzyme reactions, serum inactivation, and quality control procedures.
When operating near 100°C, users should expect increased water evaporation. Maintaining the correct water level and using the supplied stainless-steel lid helps improve temperature stability, reduce evaporation, and ensure reliable long-term operation.
The DragLab Drying Oven Series features a high-quality AISI 304 (EN 1.4301) stainless steel chamber, with all interior surfaces manufactured from this corrosion-resistant material to ensure excellent durability, hygiene, and easy cleaning. The chamber is specifically designed to withstand continuous exposure to elevated temperatures while providing long-term reliability in demanding laboratory environments.
The standard shelves are chrome-plated steel, offering strong support for laboratory samples and equipment while ensuring stable performance during routine heating and drying applications. In addition, the oven is fitted with a synthetic rubber door gasket that helps maintain an effective seal to minimize heat loss and improve temperature stability throughout the heating cycle.
Together, these carefully selected materials provide excellent resistance to corrosion, simplify routine maintenance, and contribute to the reliable thermal performance required in research, industrial, quality control, educational, and pharmaceutical laboratories.
Yes. DragLab Water Still systems are designed for reliable continuous operation, making them suitable for laboratories with daily or high-volume distilled water requirements. Automatic control features, including water level and safety protection systems, help maintain stable distilled water production while minimizing manual intervention. When installed correctly and maintained according to the user manual, DragLab Water Still systems provide dependable performance for routine laboratory operations in research, clinical, pharmaceutical, and industrial environments.
Choose your DragLab Water Still based on your daily distilled water demand. The series offers capacities from 2 L/h to 25 L/h to suit laboratories of all sizes.
- DS 2000 (2 L/h): Ideal for teaching, research, and small laboratories with low daily water consumption.
- DS 4000 (4 L/h): A versatile choice for universities, QC laboratories, and routine laboratory applications requiring a balance of capacity and efficiency.
- DS 8000 (8 L/h): Designed for medium-sized laboratories with continuous distilled water demand, including pharmaceutical, biotechnology, and industrial QC laboratories.
- DS 8008 (8 L/h): Ideal for laboratories requiring continuous water production with integrated distilled water storage for added convenience.
- DS 8012 (12 L/h): Recommended for hospitals and central laboratories requiring a higher daily distilled water output.
- DS 8025 (25 L/h): Best suited for large laboratories, industrial facilities, and centralized water supply applications with high-volume production needs.
If you are unsure which model is right for your laboratory, the DragLab team can help you select the most suitable solution based on your application and daily water consumption.
The DragLab Water Bath Series is designed to provide precise and stable temperature control for routine laboratory applications. The digital controller continuously monitors and regulates the water temperature to maintain the selected setpoint throughout operation.
Accurate temperature control is particularly important for applications such as microbiology, biotechnology, pharmaceutical quality control, food testing, and biochemical analysis, where even small temperature deviations may influence experimental results.
Actual sample temperature is affected not only by controller accuracy but also by proper water circulation, adequate water level, sample loading, and allowing sufficient time for the bath to stabilize before measurements are taken.
The DragLab Drying Oven Series supports fully programmable operation with a timer that can be set for up to 999 hours and 59 minutes, making it suitable for both short heating procedures and extended laboratory processes that require continuous temperature control over long periods.
The programmable timer allows users to accurately define the heating duration according to their specific application, improving process consistency and reducing the need for continuous operator supervision. In addition, the controller includes a Set Point Wait function, which starts the timer only after the chamber has reached the programmed temperature. This ensures that the full heating period is applied under the correct thermal conditions, providing more accurate and repeatable results for drying, conditioning, curing, material testing, and other laboratory applications.
This combination of long-duration timing capability and intelligent timer control makes the DragLab Drying Oven Series well suited for routine laboratory work as well as applications requiring precise and reproducible thermal processing.
Yes. Every model in the DragLab Water Bath Series is equipped with an integrated circulation pump that continuously moves water throughout the bath. Continuous circulation minimizes temperature differences within the tank, reduces cold spots, and provides more uniform heating than static water baths that rely only on natural convection.
Uniform temperature distribution is particularly important when multiple samples are processed simultaneously or when large sample loads are placed in the bath. Continuous circulation also helps the bath recover more quickly after cold samples are introduced, maintaining consistent thermal conditions throughout the working area.
Yes. The timer can be configured for long-duration operation of up to 999 hours and 59 minutes. Continuous operation beyond this configuration or specific continuous-use recommendations should follow the laboratory's operating procedures and maintenance schedule.
Although these terms are often used interchangeably, they describe different aspects of temperature performance.
- Temperature accuracy indicates how closely the measured water temperature matches the selected setpoint.
- Temperature stability describes how consistently the controller maintains the same temperature over time at a fixed measurement point.
- Temperature uniformity refers to how similar the temperature is at different locations throughout the water bath.
For most laboratory applications, temperature uniformity is the characteristic that has the greatest impact on the samples, because it determines whether all samples experience the same heating conditions. The DragLab Water Bath Series improves temperature uniformity by continuously circulating water throughout the bath using its integrated circulation pump.
Yes. Every model in the DragLab Water Bath Series includes an integrated circulation pump as standard. The pump continuously circulates water throughout the bath during operation, helping to maintain stable and homogeneous temperature conditions.
Compared with static water baths, continuous water circulation offers several important advantages:
- Improved temperature uniformity
- Faster heating of samples
- Reduced temperature gradients
- Faster recovery after cold samples are introduced
- More consistent heating across the entire bath
Because circulation is included as standard on every DragLab model, laboratories benefit from improved thermal performance without requiring optional upgrades.
Under normal operating conditions, the DragLab Water Bath Series typically reaches the selected temperature within approximately 10–15 minutes, depending on the selected model, water volume, initial water temperature, ambient laboratory conditions, and the target temperature.
Every model is equipped with an integrated water circulation system that continuously circulates water throughout the bath, promoting rapid and uniform heat distribution while reducing temperature gradients during the heating process.
To achieve the fastest heat-up performance, fill the bath to the recommended water level, use the supplied stainless-steel lid to minimize heat loss, and allow the bath to reach the set temperature before introducing large quantities of cold samples. Actual heat-up time may vary depending on the operating conditions.
Yes. The DragLab Drying Oven Series is equipped with a gas expansion safety thermostat, providing independent over-temperature protection to help protect both the oven and processed materials.
The DragLab Water Bath Series is designed for rapid temperature recovery through continuous water circulation. When cold or refrigerated samples are introduced into the bath, the integrated circulation pump immediately distributes heat throughout the tank, helping restore uniform temperature more quickly than static water baths.
The actual recovery time depends on the quantity, size, and temperature of the samples, as well as the selected bath model and operating temperature. To achieve the fastest recovery, users should avoid overloading the bath and ensure that water can circulate freely around all containers.
Yes. The DragLab Drying Oven Series allows users to select either degrees Celsius (°C) or degrees Fahrenheit (°F) directly through the controller settings, providing greater flexibility for laboratories that follow different temperature measurement standards.
This feature enables users to work with the unit of measurement most appropriate for their laboratory protocols, regulatory requirements, or regional preferences without the need for manual temperature conversions. The selected temperature unit is applied consistently to the displayed setpoint and actual chamber temperature, helping to simplify operation and reduce the risk of conversion errors.
Whether using the Digital Display (DO Series) or the Touch Screen (TO Series), changing the temperature unit is straightforward and can be performed through the controller interface, allowing the oven to adapt easily to a wide range of laboratory environments and international users.
Yes. The DragLab Drying Oven Series includes a programmable temperature alarm function that allows users to configure an alarm value through the controller settings. This feature provides an additional level of process monitoring by helping users detect abnormal operating conditions or unexpected temperature deviations during operation.
When the measured chamber temperature reaches the configured alarm threshold, the controller activates an alarm to alert the operator, enabling a timely response and helping to protect valuable samples and laboratory processes. This function is particularly useful for long-duration heating cycles, unattended operation, and applications where maintaining the desired temperature is critical.
Yes. The DragLab Drying Oven Series features a Delayed Start function that allows users to schedule the heating cycle to begin automatically after a predefined delay. This feature provides greater flexibility for laboratory workflows, enabling heating processes to start at a convenient time while reducing the need for manual intervention and improving operational efficiency.
Yes. The DragLab Incubator Series supports continuous operation. The programmable timer can be set from 1 minute to 99 hours and 59 minutes, or configured for continuous operation, depending on the application requirements.
The DragLab Incubator Series uses a programmable adaptive PID microprocessor controller together with a forced-air circulation system to maintain accurate, stable, and homogeneous temperature distribution throughout the chamber. An automatically adjustable quiet air turbine continuously circulates heated air, helping to minimize temperature variations and ensure that all samples are exposed to consistent incubation conditions.
The PID controller continuously monitors the chamber temperature and automatically adjusts the heating system to maintain the selected setpoint with reliable stability. The timer function supports operation from 1 minute to 99 hours and 59 minutes, as well as continuous operation, while the set-point wait function ensures that timing begins only after the chamber has reached the programmed temperature.
Depending on the model, all operating parameters—including temperature, timer settings, and system functions—are managed through either a 7-segment digital display on the DI Series or an intuitive touch screen interface on the TI Series, providing simple and reliable operation for routine laboratory applications.
DragLab Water Still systems are equipped with multiple safety features to ensure reliable and secure laboratory operation. Depending on the model, these include automatic low water level protection, over-temperature protection, and automatic shut-off to help prevent damage caused by insufficient water supply or overheating. These integrated safety systems protect both the equipment and the user while supporting stable, unattended operation during routine laboratory use.
Yes. The DragLab Incubator Series allows users to adjust the temperature during operation. Simply access the Set Temperature screen, enter the new temperature setpoint, and confirm the change. The programmable PID microprocessor controller automatically responds by regulating the heating system until the chamber reaches the newly selected temperature.
Throughout operation, the display continuously shows both the actual chamber temperature and the programmed set temperature, allowing users to monitor the temperature adjustment in real time. This feature provides flexibility when incubation protocols require different temperature stages or when operating conditions need to be modified during a run.
On DI Series models, temperature adjustments are made using the digital controller, while TI Series models (TI 30, TI 55, TI 80, and TI 120) provide an intuitive touch-screen interface for quick and convenient temperature changes. Any new temperature setting should remain within the specified operating range of the DragLab Incubator Series.
If the feed water supply is interrupted, DragLab Water Still systems are designed to automatically activate their built-in protection features to help prevent overheating and protect the heating element from damage. Once a normal water supply is restored, the system can resume safe operation according to the model specifications and operating conditions. This protection helps ensure reliable performance while reducing the risk of equipment damage and unexpected downtime.
The DragLab Incubator Series typically reaches the programmed temperature in approximately 12 minutes under normal operating conditions.
The actual heating time may vary depending on factors such as the selected temperature, ambient laboratory conditions, chamber size, and the sample load inside the incubator.
The incubator uses an adaptive PID microprocessor controller together with an automatically adjustable forced-air circulation system to provide rapid heating, homogeneous temperature distribution, and stable temperature control. During operation, both the actual chamber temperature and the set temperature can be monitored on the controller display.
The oven incorporates multiple safety features, including:
- Independent over-temperature protection
- Audible alarm
- Visual alarm
- Auto-diagnostic system
- Independent temperature safety device compliant with DIN 12880
- Class I electrical protection
- IP20 enclosure protection
These features help protect both the equipment and laboratory personnel during normal operation.
Yes. DragLab Water Still systems are designed to support reliable unattended operation during normal laboratory use. Automatic water level control and integrated safety protection help maintain stable distilled water production while reducing the need for continuous operator supervision. For safe and optimal performance, the system should always be installed, operated, and maintained according to the user manual and laboratory safety procedures.
Yes. The DragLab Drying Oven Series complies with recognized laboratory equipment standards, including:
- DIN 12880
- EN 61010-1
- EN 61010-2-010
- EN 61326-1
- EU Directives 2014/35/EU and 2014/30/EU
These standards demonstrate compliance with electrical safety, temperature protection, and electromagnetic compatibility requirements.
When the door of the DragLab Incubator Series is opened during operation, both the heating system and the circulation fan automatically stop while the door remains open. This helps protect the system but also allows heat to escape from the chamber, causing the internal temperature to decrease.
Once the door is closed, the incubator automatically resumes operation. The programmable PID microprocessor controller and forced-air circulation system work together to restore the chamber to the selected temperature and maintain homogeneous temperature distribution.
For the best incubation performance and temperature stability, the door should be opened only when necessary and closed promptly. The operating manual also warns against leaving the door open during operation, as prolonged opening may cause the appliance to overheat and create a fire hazard.
The DragLab Incubator Series is designed to restore the chamber temperature quickly after the door is closed by using an adaptive PID microprocessor controller combined with an automatically adjustable forced-air circulation system.
The actual recovery time depends on several factors, including the chamber size, the set temperature, the ambient laboratory conditions, the sample load, and how long the door remains open.
To minimize temperature fluctuations, the door should be opened only when necessary and kept open for the shortest possible time.
Yes. The DragLab Incubator Series is designed for routine laboratory incubation and supports continuous operation with programmable temperature and timer functions. It also incorporates safety features, including an independent over-temperature safety device, an automatic diagnostic alarm system, and automatic shutdown of the heating system and circulation fan when the door is opened.
For safe and reliable operation, the incubator should always be installed, operated, and maintained in accordance with the operating manual and the laboratory's established safety procedures.
The DragLab Incubator Series is designed to provide precise and stable temperature control for routine laboratory applications. It offers a temperature accuracy of ±0.3% of full scale, ensuring reliable temperature regulation across the operating range. In addition, the incubator features a temperature fluctuation of just 0.1°C, helping maintain stable incubation conditions for sensitive samples.
The DragLab Incubator Series operates over a temperature range from 20°C above ambient temperature up to 100°C, using a programmable PID microprocessor controller and an automatically adjustable forced-air circulation system to achieve accurate and homogeneous temperature control throughout the chamber.
The DragLab Incubator Series is designed to maintain highly stable chamber temperatures during operation. It features a temperature fluctuation of only 0.1°C, helping provide consistent incubation conditions for sensitive laboratory applications.
To ensure reliable temperature stability, the incubator combines a programmable PID microprocessor controller with an automatically adjustable forced-air circulation system, which continuously regulates and distributes heat evenly throughout the chamber. This design promotes stable and homogeneous temperature conditions across the entire incubation process.
Yes. Distilled water produced by a DragLab Water Still can be used as feed water for additional laboratory water purification systems, such as deionization (DI) or ultrapure water systems, when higher water purity is required. Using distilled water as a pre-treatment source helps reduce the load on downstream purification systems, extends the service life of purification cartridges or resins, and contributes to the consistent production of high-purity laboratory water for specialized analytical and research applications.
The DragLab Incubator Series uses a Pt100 temperature sensor (DIN Class A) with a 2-wire circuit for accurate temperature measurement and control. This high-precision platinum resistance temperature detector (RTD) provides reliable temperature monitoring and supports the incubator's precise temperature regulation.
Working together with the programmable PID microprocessor controller, the Pt100 DIN Class A sensor helps the incubator achieve accurate, stable, and consistent temperature control throughout the chamber, making it suitable for demanding laboratory incubation applications.
Technical support and genuine spare parts for the DragLab Drying Oven Series are available through DragLab's global network of authorized distributors and service partners. DragLab provides professional technical assistance, troubleshooting support, maintenance guidance, and long-term spare parts availability to help ensure reliable equipment operation throughout the product's service life.
When requesting technical assistance or replacement parts, customers should provide the oven's model number, serial number, and, if possible, a description of the issue or the required spare part. This information enables the support team to identify the correct product configuration, recommend the appropriate solution, and provide faster, more efficient service.
A DragLab Water Still purifies water through the distillation process, while an RO (Reverse Osmosis) system uses a semi-permeable membrane to remove dissolved contaminants. Distillation effectively removes a broad range of impurities, including most dissolved minerals, microorganisms, and many organic contaminants, producing high-quality distilled water for routine laboratory applications. RO systems are often preferred where lower operating costs or larger volumes of purified water are required. The most suitable solution depends on your laboratory application, required water quality, daily water consumption, and operating requirements.
Yes. The DragLab Incubator Series uses an adaptive multifunctional PID microprocessor controller to regulate chamber temperature accurately and maintain the selected setpoint throughout the incubation process.
Working in combination with a Pt100 DIN Class A temperature sensor and an automatically adjustable forced-air circulation system, the PID controller continuously monitors and adjusts the heating system to provide precise, stable, and homogeneous temperature conditions across the chamber.
No. The DragLab Drying Oven Series is not designed for heating materials that release flammable, explosive, or hazardous vapors during the heating process. Using such materials may create serious safety hazards, including the risk of fire, explosion, or damage to the equipment, and is outside the intended use of the oven.
The oven is designed for the drying, heating, conditioning, and thermal treatment of non-flammable materials under controlled laboratory conditions. Before processing any sample, users should evaluate its thermal properties and ensure that it does not generate combustible gases or hazardous fumes when heated. Following these precautions helps protect laboratory personnel, maintain equipment safety, and ensure reliable long-term operation.
The DragLab Drying Oven Series is capable of operating at temperatures suitable for dry-heat applications, including processes that may require elevated temperatures. However, the operating manual does not validate or certify the oven as a medical sterilizer, and the equipment is not intended to replace validated sterilization systems used in healthcare or regulated pharmaceutical environments.
Laboratories requiring validated dry-heat sterilization or depyrogenation processes should follow the applicable regulatory standards, validated operating procedures, and qualification protocols to ensure compliance with their specific application. The DragLab Drying Oven Series is primarily designed for drying, heating, conditioning, curing, material testing, and other general laboratory thermal processing applications rather than validated medical sterilization.
The DragLab Incubator Series uses a forced-air circulation system, not natural convection. An automatically adjustable quiet air turbine continuously circulates air throughout the chamber to promote homogeneous temperature distribution and maintain stable incubation conditions.
Combined with the adaptive multifunctional PID microprocessor controller and the Pt100 DIN Class A temperature sensor, the forced-air circulation system helps ensure accurate, stable, and uniform temperature control across the entire chamber.
DragLab uses forced-air circulation to maintain homogeneous temperature distribution throughout the chamber and to help keep the chamber temperature close to the selected setpoint, even when the incubator is fully loaded. This design supports reliable and reproducible incubation conditions across a wide range of laboratory applications.
Yes. Because the oven continuously circulates heated air throughout the chamber, moisture evaporates more efficiently from exposed samples. This improves drying performance but may increase moisture loss in uncovered or moisture-sensitive materials. When necessary, samples should be placed in suitable containers according to the laboratory protocol.
Yes, provided all samples require the same operating temperature and are chemically compatible. Users should avoid combining materials that may contaminate one another or release incompatible vapors during heating.
Distillation is highly effective at removing microorganisms and many impurities from water. Under normal operating conditions, the DragLab Water Still Series produces high-quality distilled water suitable for a wide range of routine laboratory applications. However, if water that is certified bacteria-free, pyrogen-free, or endotoxin-free is required for highly specialized applications, additional validated purification or sterilization processes may be necessary, depending on the specific laboratory requirements.
Yes. The door may be opened briefly when necessary. However, frequent or prolonged door opening allows heat to escape, which may extend the time required for the chamber to return to the programmed temperature.
Yes. The DragLab Incubator Series features an automatically adjustable forced-air circulation system with a quiet air turbine. During normal operation, the airflow is regulated automatically to promote homogeneous temperature distribution and maintain stable incubation conditions throughout the chamber.
The current product documentation does not indicate that manual airflow adjustment by the user is available. Airflow regulation is performed automatically by the incubator as part of its normal temperature control system.
Samples should be positioned to allow free air circulation around each item. Overloading shelves or blocking airflow may reduce temperature uniformity and drying efficiency. Heavy loads should remain within the maximum permitted shelf and chamber capacities specified for the selected model.
Yes. The forced-air circulation system in the DragLab Incubator Series can affect the moisture content of samples during incubation.
The incubator uses an automatically adjustable forced-air circulation system to ensure homogeneous temperature distribution and maintain stable incubation conditions throughout the chamber. As the circulating air promotes efficient heat transfer, it can also increase moisture evaporation from exposed samples, particularly during long incubation periods or when working with uncovered containers.
For moisture-sensitive applications, samples should be placed in appropriately sealed or covered containers whenever required by the laboratory protocol.
The DragLab Water Bath Series incorporates multiple safety features to support reliable laboratory operation and protect both the equipment and the user during routine use.
Key safety features include:
- Over-temperature protection to help prevent excessive heating.
- Low-water protection that helps protect the heating system if the water level becomes too low.
- Integrated water circulation pump for stable and uniform heat distribution.
- Digital temperature controller for accurate temperature regulation.
- Grounded electrical design for safe laboratory operation.
- Durable stainless-steel bath chamber with excellent corrosion resistance.
- Drain valve for safe and convenient water replacement.
- Safety labels and operating instructions to promote correct equipment use.
For maximum safety, the water bath should always be operated according to the operating manual and the laboratory's established safety procedures.
The chamber of the DragLab Incubator Series is constructed from AISI 304 (EN 1.4301) stainless steel, providing excellent corrosion resistance, durability, and easy cleaning for routine laboratory applications.
The high-quality stainless-steel chamber is designed to withstand repeated laboratory use while supporting a clean and reliable incubation environment for research, clinical, pharmaceutical, food, and quality control laboratories.
The DragLab Water Bath Series is equipped with a low-water protection system designed to help protect the heating system from operating without sufficient water.
If the water level drops below the safe operating level due to evaporation or insufficient filling, the protection system helps prevent damage to the heating components. When this occurs, users should switch off the unit if necessary, allow it to cool if required, refill the bath with distilled water to the recommended level, and verify normal operation before continuing laboratory work.
Regularly checking the water level is particularly important during prolonged operation or when the bath is used at elevated temperatures, where evaporation occurs more rapidly.
Each shelf in the DragLab Drying Oven Series is designed to support a maximum load of 15 kg. This limit should not be exceeded to maintain safe operation and reliable performance.
The DragLab Water Still Series is designed to produce high-quality distilled water for a wide range of laboratory applications. However, compliance with specific pharmacopoeia standards, such as the European Pharmacopoeia (Ph. Eur.), United States Pharmacopeia (USP), or other regulatory requirements, depends on the complete water purification and quality control process. Laboratories should verify that the produced water meets the applicable pharmacopoeial specifications for their intended application.
Yes. The DragLab Incubator Series is equipped with an inner tempered safety glass door, allowing users to monitor samples without fully exposing the chamber to the external environment.
This design helps minimize heat loss and temperature fluctuations when the outer door is opened, supporting stable incubation conditions while enabling convenient observation of samples.
Yes. The DragLab Water Bath Series incorporates over-temperature protection to provide an additional level of safety during operation.
This protection helps prevent the bath from exceeding safe operating conditions in the event of abnormal temperature control or unexpected operating conditions, thereby protecting both the equipment and laboratory samples.
Although this safety feature provides additional protection, users should always verify the selected operating temperature before starting each procedure and monitor the equipment according to their laboratory's standard operating procedures.
The maximum permitted chamber load depends on the selected model and the maximum number of shelf positions available. Each shelf is designed to support a maximum distributed load of 15 kg, and users should ensure that samples are evenly distributed across the shelves to maintain proper airflow and stable heating performance.
The maximum chamber load for each model is as follows:
|
Model |
Maximum Shelf Positions |
Maximum Load per Shelf |
Maximum Total Chamber Load |
|
DO 30 / TO 30 |
5 |
15 kg |
75 kg |
|
DO 55 / TO 55 |
8 |
15 kg |
120 kg |
|
DO 80 / TO 80 |
10 |
15 kg |
150 kg |
|
DO 120 / TO 120 |
11 |
15 kg |
165 kg |
To achieve the best heating performance, users should distribute the load evenly across the shelves and avoid blocking the airflow inside the chamber. The maximum permitted chamber load must never be exceeded, as overloading may reduce temperature uniformity, restrict air circulation, and place unnecessary stress on the shelves and oven components.
All DragLab Incubator Series models are supplied as standard with two chrome-plated wire shelves, providing flexible support for a wide variety of laboratory containers and samples.
Additional shelves can be installed to increase chamber capacity. The maximum number of shelves varies by model:
|
Model |
Standard Shelves |
Maximum Number of Shelves |
|
DI 30 / TI 30 |
2 |
5 |
|
DI 55 / TI 55 |
2 |
8 |
|
DI 80 / TI 80 |
2 |
10 |
|
DI 120 / TI 120 |
2 |
11 |
Additional wire shelves are available as optional accessories, allowing users to configure the chamber according to their application requirements. Each shelf has a maximum load capacity of 15 kg, ensuring reliable support for laboratory samples and containers.
No. The DragLab Water Bath Series is not intended for heating flammable, explosive, or hazardous liquids that may release combustible or toxic vapors during heating.
Heating such materials may create significant safety hazards, including fire, explosion, or exposure to hazardous substances, and falls outside the intended use of the equipment.
Before heating any sample, laboratories should review the material's safety data and confirm that it is suitable for heating in a laboratory water bath. Appropriate laboratory safety procedures should always be followed.
For optimum performance:
- Install the oven with the recommended clearances.
- Do not overload the chamber or shelves.
- Allow proper airflow around samples.
- Clean the chamber regularly.
- Perform preventive maintenance annually.
- Operate the oven within the specified environmental conditions.
Following these recommendations helps maintain temperature stability, drying efficiency, and long-term reliability.
The DragLab Water Bath Series is designed for general laboratory heating applications involving compatible, non-hazardous materials under controlled laboratory conditions.
The equipment is not specifically designed or certified for handling hazardous chemicals, explosive substances, or materials that generate flammable or toxic vapors during heating.
If hazardous materials must be processed, laboratories should use equipment specifically designed and approved for those applications and follow all applicable safety regulations and institutional procedures.
Each shelf in the DragLab Incubator Series supports a maximum load of 15 kg.
The maximum permitted chamber load depends on the model:
- DI/TI 30: 75 kg
- DI/TI 55: 110 kg
- DI/TI 80: 150 kg
- DI/TI 120: 170 kg
Users should ensure that these load limits are not exceeded to maintain safe and reliable operation.
The DragLab Water Still Series is designed for reliable day-to-day laboratory operation. During use, the unit generates normal operating sounds associated with water heating, boiling, condensation, and water flow. Under normal operating conditions, the noise level is suitable for typical laboratory environments and should not interfere with routine laboratory work. If unusual or excessive noise is observed, the system should be inspected to ensure it is installed correctly and operating according to the user manual.
Each shelf in the DragLab Incubator Series supports a maximum load of 15 kg.
The maximum permitted chamber load depends on the model:
- DI/TI 30: 75 kg
- DI/TI 55: 110 kg
- DI/TI 80: 150 kg
- DI/TI 120: 170 kg
Users should ensure that these load limits are not exceeded to maintain safe and reliable operation.
Yes. The DragLab Drying Oven Series is designed to provide excellent temperature uniformity throughout the chamber. Under normal operating conditions, the temperature difference within the working chamber is typically within ±1°C, helping to ensure consistent heating performance across different shelf levels.
This high level of temperature uniformity is achieved through the combination of an automatically adjustable forced-air circulation system and an adaptive programmable PID microprocessor controller, which work together to distribute heated air evenly and maintain stable operating conditions throughout the heating cycle.
Proper sample loading, adequate spacing between items, and unobstructed airflow further contribute to achieving the best possible temperature uniformity and repeatable results for drying, conditioning, curing, material testing, and other laboratory heating applications.
The DragLab Water Bath Series is designed to support continuous laboratory operation and incorporates safety features such as over-temperature protection and low-water protection to promote reliable performance.
However, as with all laboratory heating equipment, the bath should only be left operating unattended when this is permitted by the laboratory's safety procedures and risk assessment. Before leaving the unit unattended, users should ensure that:
- The correct operating temperature has been selected.
- The bath contains sufficient distilled water.
- The lid is properly positioned to reduce evaporation.
- The samples are suitable for prolonged heating.
- No flammable or hazardous materials are present.
Following these precautions helps ensure safe and reliable long-term operation.
Feed water consumption varies by model and distilled water output. The typical feed water consumption for the DragLab Water Still Series is:
- DS2000: 40 L/h
- DS4000: 40 L/h
- DS8000: 40 L/h
- DS8008: 80 L/h
- DS8012: 135 L/h
- DS8025: 250 L/h
These values are specified under normal operating conditions. Please refer to the product datasheet for detailed technical specifications and installation requirements.
The DragLab Incubator Series is designed with multiple safety features to support reliable, safe, and compliant laboratory operation. These include:
- Automatic thermostatic protection to help maintain stable operating conditions.
- Independent over-temperature safety device with an adjustable alarm limit for enhanced temperature protection.
- Audible alarm that can be enabled or disabled according to user preferences.
- Automatic diagnostic system for fault detection and troubleshooting.
- Automatic shutdown of the heating system and circulation fan when the door is opened, helping reduce heat loss and improve operational safety.
- Class I electrical equipment for electrical safety.
- IP20 protection class.
- Compliance with internationally recognized safety and EMC standards, including DIN 12880, EN 61010-1, EN 61010-2-010, EN 61326-1, and the applicable European Directives 2014/35/EU (Low Voltage Directive) and 2014/30/EU (Electromagnetic Compatibility Directive).
These integrated safety features help ensure dependable operation while protecting both laboratory personnel and valuable samples.
Under normal operating conditions, the DragLab Drying Oven Series typically reaches the set temperature within approximately 20 minutes, depending on the selected model, chamber size, target temperature, ambient conditions, and sample load.
The oven is equipped with an adaptive programmable PID microprocessor controller and an automatically adjustable forced-air circulation system, which work together to achieve rapid, stable, and uniform heating throughout the chamber while minimizing temperature fluctuations.
To achieve the best heat-up performance, users should avoid overloading the chamber, allow adequate spacing between samples to maintain proper airflow, and minimize unnecessary door openings during operation. Actual heat-up time may vary depending on the operating conditions.
If the DragLab Water Bath Series displays an alarm, behaves abnormally, or does not operate as expected, users should first stop the current procedure if necessary and verify the operating conditions.
Check that:
- The water level is within the recommended operating range.
- The selected temperature is appropriate.
- The power supply is stable.
- The bath is installed correctly.
- The ventilation around the equipment is unobstructed.
If the abnormal condition persists after these checks, discontinue operation and contact your authorized DragLab distributor or technical service representative. When requesting assistance, provide the model number, serial number, and a clear description of the observed condition to help ensure efficient technical support.
Power consumption varies depending on the model and distilled water production capacity. The rated power consumption for the DragLab Water Still Series is:
- DS2000: 2000 Watt
- DS4000: 3000 Watt
- DS8000: 3000 Watt
- DS8008: 6000 Watt
- DS8012: 9000 Watt
- DS8025: 18000 Watt
Each model is designed to provide efficient and reliable distilled water production while maintaining consistent laboratory performance. For complete electrical requirements, including voltage and current ratings, please refer to the product datasheet.
If an alarm appears on the display, first verify the incubator's operating conditions and ensure that it is being used within the specified operating limits. Check that the door is properly closed, the power supply is stable, and the temperature settings are appropriate for your application.
The DragLab Incubator Series features an automatic diagnostic system to assist with fault detection and analysis. If the alarm remains after correcting any obvious operating issues, discontinue use of the incubator and contact your authorized DragLab distributor or technical support for further assistance.
Yes. The high-quality distilled water produced by the DragLab Water Still Series is suitable for a wide range of laboratory applications, including reagent preparation, glassware rinsing, media preparation, instrument feeding, and general laboratory use. For applications requiring ultrapure, pyrogen-free, or pharmacopoeia-grade water, additional purification or validation may be required.
No. Flammable, explosive, or volatile substances must not be placed inside the DragLab Incubator Series. The incubator is designed for laboratory incubation applications and must not be used with materials that may produce flammable, explosive, or corrosive vapors.
To ensure safe operation, always use the incubator in accordance with the operating manual and laboratory safety procedures. Using incompatible materials may create a safety hazard and can damage the equipment.
Yes, the DragLab Drying Oven Series is designed to support continuous and long-duration laboratory heating applications, including overnight operation, provided that the oven is installed, operated, and monitored in accordance with the operating manual and the laboratory's safety procedures.
The oven features an adaptive programmable PID microprocessor controller, an automatically adjustable forced-air circulation system, a programmable timer (up to 999 hours 59 minutes), and an over-temperature alarm to help maintain stable operating conditions during extended heating cycles.
Before leaving the oven unattended, users should ensure that the samples being processed are suitable for prolonged heating, that the chamber is not overloaded, and that no flammable, explosive, or hazardous materials are present. The door should remain securely closed throughout the heating cycle to maintain temperature stability and ensure safe, reliable operation.
Yes. The cooling water discharged from the DragLab Water Still Series can often be reused for non-critical applications, depending on local laboratory practices and water quality requirements. For example, it may be used for general cleaning, irrigation, or other utility purposes, helping to reduce overall water consumption. The suitability of reuse should be evaluated according to local regulations and the intended application.
The DragLab Incubator Series is intended for general laboratory incubation applications and must not be used with materials that generate flammable, explosive, or corrosive vapors.
When working with hazardous substances, users should ensure that the materials are compatible with the incubator and comply with all applicable laboratory safety procedures. Applications involving hazardous materials that may create a fire, explosion, or corrosion risk are not suitable for this incubator.
The distilled water produced by the DragLab Water Still Series is typically discharged at a temperature of approximately 40–50°C under normal operating conditions. Because the water may still be hot immediately after the distillation process, users should handle it with care to avoid the risk of burns. If cooler water is required for a specific application, allow the distilled water to cool before use or transfer it to a suitable storage container.
The DragLab Water Still Series is designed to operate with cooling water at a temperature between 10°C and 35°C. Maintaining the cooling water within this recommended range helps ensure efficient steam condensation, stable distilled water production, and reliable overall system performance. For optimum operation, the cooling water supply should also provide adequate flow and a water pressure within the recommended operating range.
Under normal operating conditions, the discharged cooling water (waste water) from the DragLab Water Still Series is typically between 50°C and 65°C. The exact outlet temperature may vary depending on the inlet cooling water temperature, water flow rate, model, and operating conditions. Because the discharged water may be hot, it should be directed to a suitable drain or handled with appropriate care.
Check the spelling, try a different term or choose another category above. Or ask us directly: +49 6196 400816, info@drag-lab.de.
Planning a purchase?
Send us your request. We will prepare a quote and help you choose the right device.