The calibration interval for the DragLab Incubator Series depends on the laboratory's quality management system, applicable regulatory requirements, and the frequency of use. Laboratories operating under accredited quality systems should establish a calibration schedule that complies with their internal procedures and relevant standards.

To help ensure continued measurement accuracy, calibration should be performed using a certified reference standard. A calibration certificate is available for the DragLab Incubator Series as an optional accessory.

Yes. The DragLab Incubator Series includes a temperature calibration function that can be accessed through the controller menu. This feature allows temperature calibration to help maintain accurate temperature control when performed according to the operating instructions.

For reliable results, temperature calibration should be carried out using an appropriate certified reference thermometer and in accordance with the laboratory's quality procedures.

The DragLab Incubator Series is designed for easy cleaning and maintenance. Its chamber is constructed from smooth AISI 304 stainless steel, providing excellent durability and a surface that is easy to keep clean.

For routine cleaning:

  • Always disconnect the incubator from the power supply before performing any cleaning or maintenance.
  • Clean the chamber, shelves, and inner tempered glass door regularly to maintain hygienic operating conditions and reliable performance.
  • Wipe surfaces with a soft, damp cloth. If required, alcohol-based cleaning agents may be used.
  • Do not use acidic, chlorine-based, or other corrosive cleaning agents, as they may damage the stainless-steel surfaces and other components.

Regular cleaning helps maintain a clean incubation environment and supports the long-term performance of the DragLab Incubator Series.

The DragLab Incubator Series should undergo preventive maintenance at least once per year to help ensure reliable operation and long-term performance.

Maintenance should be performed by authorized and qualified service personnel in accordance with the operating manual. In addition to scheduled annual maintenance, users should keep the incubator clean and regularly inspect it for any signs of damage or abnormal operation. If any faults or alarms occur, discontinue operation and contact your authorized DragLab distributor or technical support.

Yes. The DragLab Incubator Series chamber may be cleaned using alcohol-based disinfectants or cleaning agents as part of routine maintenance.

However, acidic, chlorine-based, or other corrosive cleaning agents must not be used, as they may damage the AISI 304 stainless steel chamber and other components.

Before cleaning or disinfecting the chamber, always disconnect the incubator from the power supply and follow the operating manual and your laboratory's cleaning procedures.

No. The DragLab Incubator Series does not include a dedicated chamber disinfection or sterilization function.

To maintain hygienic operating conditions, the chamber should be cleaned regularly using appropriate cleaning agents in accordance with the operating manual. The AISI 304 stainless steel chamber, removable shelves, and inner tempered safety glass door are designed for easy cleaning.

For routine cleaning, alcohol-based cleaning agents may be used, while acidic, chlorine-based, or other corrosive cleaning agents must not be used. Always disconnect the incubator from the power supply before performing any cleaning or maintenance procedures.

To help ensure reliable operation and long service life, the following components of the DragLab Incubator Series should be inspected regularly:

  • Chamber interior to ensure it remains clean and free from contamination.
  • Chrome-plated wire shelves for cleanliness, proper installation, and signs of damage.
  • Inner tempered safety glass door for cleanliness and integrity.
  • Door gasket (seal) to ensure proper sealing and minimize heat loss.
  • Power cord and electrical connections for any signs of wear or damage.
  • General operating condition of the incubator, including normal temperature control and alarm status.

In addition, periodic calibration and verification of temperature performance are recommended whenever required by the laboratory's quality management system or standard operating procedures. Preventive maintenance should be performed at least once per year by authorized and qualified service personnel.

To maximize the service life of the DragLab Incubator Series, install the incubator according to the recommended clearances, operate it within the specified ambient conditions, clean the chamber regularly, avoid exceeding the permitted shelf and chamber loads, and perform routine inspection and calibration when required. Following the operating instructions and preventive maintenance practices helps ensure long-term, reliable performance.