Get a Quote

Knowledge Base

Answers to your most common questions

199 questions in 6 categories for 4 product series

Installation 9 questions

The DragLab Incubator Series is supplied with the essential components required for installation and routine laboratory use. The standard package includes:

  • Incubator unit
  • Power cable
  • Two chrome-plated wire shelves
  • Operating manual
  • Service manual

Depending on the model, application, or customer requirements, optional accessories may also be available, including:

  • Additional wire shelves (wire racks)
  • Calibration certificate
  • Language packages for documentation

For information about model-specific accessories or optional equipment, please contact your local DragLab distributor or authorized representative

Yes. The DragLab Incubator Series is designed for straightforward installation in laboratory environments. After placing the incubator on a stable laboratory workbench with the recommended installation clearances, simply connect it to the appropriate 230 V, 50/60 Hz electrical supply before operation.

For optimum performance, the incubator should be installed in a clean, dry, and well-ventilated location while maintaining the recommended clearance of 15 cm from the rear wall, at least 5 cm from each side, and 20 cm above the unit. Once installed, users can configure the desired temperature and timer settings through the digital display (DI Series) or touch screen interface (TI Series), allowing the incubator to be ready for routine laboratory use.

The DragLab Incubator Series should be installed on a stable, level laboratory surface in a clean, dry, and well-ventilated environment. To ensure proper airflow and cooling performance, maintain the recommended installation clearances around the unit and operate it within the specified ambient conditions.

Yes, selected models of the DragLab Incubator Series are designed for benchtop installation.

The 30 L, 55 L, and 80 L models (DI30/TI30, DI55/TI55, and DI80/TI80) can be installed on a stable laboratory bench capable of safely supporting the incubator and its maximum operating load.

The 120 L models (DI120/TI120) are not intended for benchtop installation due to their larger size and weight. They should be installed on a suitable floor-standing surface that meets the installation requirements specified in the operating manual.

For all models, adequate clearance should be maintained around the incubator to ensure proper ventilation and safe operation.

The DragLab Incubator Series operates on a 230 V, 50/60 Hz electrical supply with a rated power of 1500 W. Before installation, ensure that the laboratory power supply matches the electrical specifications of the selected model.

The DragLab Incubator Series is designed to operate in laboratory environments with an ambient temperature of +5°C to +55°C and a maximum relative humidity of 80% RH. Operating the incubator within these recommended environmental conditions helps ensure stable temperature control, reliable performance, and consistent incubation results.

For the best performance, the incubator should be installed in a clean, dry, and well-ventilated location away from direct sunlight, excessive heat sources, or areas subject to rapid temperature fluctuations. Maintaining the recommended ambient conditions also supports the efficiency of the forced-air circulation system and the programmable PID controller, helping the incubator maintain homogeneous temperature distribution throughout the chamber.

For proper ventilation, the DragLab Incubator Series should be installed with the following minimum clearances:

  • Rear: at least 15 cm
  • Each side: at least 5 cm
  • Above the unit: at least 20 cm

Maintaining these clearances allows adequate airflow and supports reliable operation.

Yes. The DragLab Incubator Series requires adequate ventilation around the unit. During installation, the recommended minimum clearances should be maintained to ensure sufficient airflow. The incubator also features forced-air circulation by a quiet, automatically adjustable air turbine, which helps maintain uniform temperature distribution inside the chamber.

Setting the incubation temperature on the DragLab Incubator Series is simple and intuitive. After switching on the incubator, access the temperature setpoint from the main operating screen by selecting the Set Temperature field. Enter the desired incubation temperature using the on-screen numeric keypad and confirm the value by pressing Enter.

Once the incubation cycle is started, the programmable PID microprocessor controller automatically heats the chamber until the selected setpoint is reached and continuously regulates the temperature to maintain stable incubation conditions. Users can also view both the actual chamber temperature and the programmed set temperature at any time from the temperature display screen, allowing easy monitoring throughout the incubation process.

On DI Series models, temperature settings are entered using the digital controller, while TI Series models (TI 30, TI 55, TI 80, and TI 120) provide an intuitive touch-screen interface for quick and convenient temperature adjustment. Always ensure that the selected temperature is within the operating range of the DragLab Incubator Series before starting the incubation cycle.

Planning a purchase?

Send us your request. We will prepare a quote and help you choose the right device.

+49 6196 400816 info@drag-lab.de