Knowledge Base
Answers to your most common questions
199 questions in 6 categories for 4 product series
General 31 questions
The DragLab Incubator Series is a range of high-performance laboratory incubators designed to provide precise, reliable, and homogeneous temperature control for routine incubation applications. Available with either a digital display (DI Series) or an intuitive touch screen interface (TI Series), the incubators feature programmable PID temperature control, forced-air circulation, and chamber capacities ranging from 30 to 120 liters.
Designed for consistent and reproducible incubation conditions, the DragLab Incubator Series is suitable for a wide range of laboratory applications, including microbiology, biotechnology, pharmaceutical research, quality control, food testing, and general scientific research. Its durable AISI 304 stainless steel chamber, user-friendly controls, and uniform temperature distribution make it an ideal solution for laboratories requiring dependable day-to-day performance.
The DragLab Incubator Series is suitable for a wide range of laboratory applications, including clinical microbiology, biotechnology, cell culture, media preparation, microbiology and bacteriology sample preparation, pharmaceutical manufacturing, food and beverage production, cosmetics, material testing, and general research laboratories.
The DragLab Incubator Series is available in four chamber capacities—30 L, 55 L, 80 L, and 120 L—with a choice of either a Digital Display (DI Series) or a Touch Screen (TI Series) interface. The available models are:
- DI 30 / TI 30 (30 L) – Compact incubators ideal for laboratories with limited bench space, educational laboratories, and routine microbiology or low-volume sample incubation.
- DI 55 / TI 55 (55 L) – Versatile models designed for everyday laboratory use, offering an excellent balance between chamber capacity and footprint for general research and quality control applications.
- DI 80 / TI 80 (80 L) – Suitable for laboratories processing larger sample volumes or running multiple incubation projects simultaneously while maintaining efficient use of laboratory space.
- DI 120 / TI 120 (120 L) – The largest incubators in the series, designed for high-throughput laboratories, pharmaceutical and industrial quality control laboratories, and research facilities requiring maximum incubation capacity.
All models feature programmable PID temperature control, forced-air circulation, an AISI 304 stainless steel chamber, and homogeneous temperature distribution. The primary difference between the DI and TI series is the user interface: DI models feature a reliable digital display for straightforward operation, while TI models offer an intuitive touch screen for easier programming and enhanced user convenience.
Choosing the right model depends on your available laboratory space, the number and size of samples you process, and your preferred control interface, while all DragLab incubators provide the same dependable incubation performance.
The DragLab Incubator Series is available with useful chamber volumes of 30 L, 55 L, 80 L, and 120 L, allowing laboratories to select the most suitable capacity for their application and sample workload.
The DragLab Incubator Series provides a temperature range from ambient +20°C up to 100°C, making it suitable for a wide variety of routine laboratory incubation applications. This range covers the temperature requirements for microbiology, cell culture, biotechnology, pharmaceutical research, food testing, and quality control laboratories.
To ensure reliable and reproducible results, the incubators are equipped with a programmable adaptive PID microprocessor controller and a forced-air circulation system that work together to maintain stable and homogeneous temperature conditions throughout the chamber. This combination helps minimize temperature variations and ensures consistent incubation performance, even when the chamber is fully loaded.
The temperature range is the same across all DI 30, DI 55, DI 80, DI 120 and TI 30, TI 55, TI 80, TI 120 models, allowing users to select the appropriate chamber capacity without compromising temperature performance.
The DragLab Incubator Series combines forced-air circulation, programmable PID temperature control, homogeneous temperature distribution compliant with DIN 12880, and durable AISI 304 stainless steel chambers to deliver reliable incubation performance. Available with either a digital display or touch screen interface, the series is designed for accurate temperature control, user-friendly operation, and dependable performance across a wide range of laboratory applications.
The DragLab Incubator Series is used across a broad range of industries, including biotechnology, pharmaceuticals, human diagnostics, food and beverage production, chemical laboratories, cosmetics manufacturing, medical research, water analysis, and research institutions requiring controlled incubation conditions.
Yes. The DragLab Incubator Series supports continuous operation. The programmable timer can be set from 1 minute to 99 hours and 59 minutes, or configured for continuous operation, depending on the application requirements.
The DragLab Incubator Series uses a programmable adaptive PID microprocessor controller together with a forced-air circulation system to maintain accurate, stable, and homogeneous temperature distribution throughout the chamber. An automatically adjustable quiet air turbine continuously circulates heated air, helping to minimize temperature variations and ensure that all samples are exposed to consistent incubation conditions.
The PID controller continuously monitors the chamber temperature and automatically adjusts the heating system to maintain the selected setpoint with reliable stability. The timer function supports operation from 1 minute to 99 hours and 59 minutes, as well as continuous operation, while the set-point wait function ensures that timing begins only after the chamber has reached the programmed temperature.
Depending on the model, all operating parameters—including temperature, timer settings, and system functions—are managed through either a 7-segment digital display on the DI Series or an intuitive touch screen interface on the TI Series, providing simple and reliable operation for routine laboratory applications.
Yes. The DragLab Incubator Series allows users to adjust the temperature during operation. Simply access the Set Temperature screen, enter the new temperature setpoint, and confirm the change. The programmable PID microprocessor controller automatically responds by regulating the heating system until the chamber reaches the newly selected temperature.
Throughout operation, the display continuously shows both the actual chamber temperature and the programmed set temperature, allowing users to monitor the temperature adjustment in real time. This feature provides flexibility when incubation protocols require different temperature stages or when operating conditions need to be modified during a run.
On DI Series models, temperature adjustments are made using the digital controller, while TI Series models (TI 30, TI 55, TI 80, and TI 120) provide an intuitive touch-screen interface for quick and convenient temperature changes. Any new temperature setting should remain within the specified operating range of the DragLab Incubator Series.
The DragLab Incubator Series typically reaches the programmed temperature in approximately 12 minutes under normal operating conditions.
The actual heating time may vary depending on factors such as the selected temperature, ambient laboratory conditions, chamber size, and the sample load inside the incubator.
The incubator uses an adaptive PID microprocessor controller together with an automatically adjustable forced-air circulation system to provide rapid heating, homogeneous temperature distribution, and stable temperature control. During operation, both the actual chamber temperature and the set temperature can be monitored on the controller display.
When the door of the DragLab Incubator Series is opened during operation, both the heating system and the circulation fan automatically stop while the door remains open. This helps protect the system but also allows heat to escape from the chamber, causing the internal temperature to decrease.
Once the door is closed, the incubator automatically resumes operation. The programmable PID microprocessor controller and forced-air circulation system work together to restore the chamber to the selected temperature and maintain homogeneous temperature distribution.
For the best incubation performance and temperature stability, the door should be opened only when necessary and closed promptly. The operating manual also warns against leaving the door open during operation, as prolonged opening may cause the appliance to overheat and create a fire hazard.
The DragLab Incubator Series is designed to restore the chamber temperature quickly after the door is closed by using an adaptive PID microprocessor controller combined with an automatically adjustable forced-air circulation system.
The actual recovery time depends on several factors, including the chamber size, the set temperature, the ambient laboratory conditions, the sample load, and how long the door remains open.
To minimize temperature fluctuations, the door should be opened only when necessary and kept open for the shortest possible time.
Yes. The DragLab Incubator Series is designed for routine laboratory incubation and supports continuous operation with programmable temperature and timer functions. It also incorporates safety features, including an independent over-temperature safety device, an automatic diagnostic alarm system, and automatic shutdown of the heating system and circulation fan when the door is opened.
For safe and reliable operation, the incubator should always be installed, operated, and maintained in accordance with the operating manual and the laboratory's established safety procedures.
The DragLab Incubator Series is designed to provide precise and stable temperature control for routine laboratory applications. It offers a temperature accuracy of ±0.3% of full scale, ensuring reliable temperature regulation across the operating range. In addition, the incubator features a temperature fluctuation of just 0.1°C, helping maintain stable incubation conditions for sensitive samples.
The DragLab Incubator Series operates over a temperature range from 20°C above ambient temperature up to 100°C, using a programmable PID microprocessor controller and an automatically adjustable forced-air circulation system to achieve accurate and homogeneous temperature control throughout the chamber.
The DragLab Incubator Series is designed to maintain highly stable chamber temperatures during operation. It features a temperature fluctuation of only 0.1°C, helping provide consistent incubation conditions for sensitive laboratory applications.
To ensure reliable temperature stability, the incubator combines a programmable PID microprocessor controller with an automatically adjustable forced-air circulation system, which continuously regulates and distributes heat evenly throughout the chamber. This design promotes stable and homogeneous temperature conditions across the entire incubation process.
The DragLab Incubator Series uses a Pt100 temperature sensor (DIN Class A) with a 2-wire circuit for accurate temperature measurement and control. This high-precision platinum resistance temperature detector (RTD) provides reliable temperature monitoring and supports the incubator's precise temperature regulation.
Working together with the programmable PID microprocessor controller, the Pt100 DIN Class A sensor helps the incubator achieve accurate, stable, and consistent temperature control throughout the chamber, making it suitable for demanding laboratory incubation applications.
Yes. The DragLab Incubator Series uses an adaptive multifunctional PID microprocessor controller to regulate chamber temperature accurately and maintain the selected setpoint throughout the incubation process.
Working in combination with a Pt100 DIN Class A temperature sensor and an automatically adjustable forced-air circulation system, the PID controller continuously monitors and adjusts the heating system to provide precise, stable, and homogeneous temperature conditions across the chamber.
The DragLab Incubator Series uses a forced-air circulation system, not natural convection. An automatically adjustable quiet air turbine continuously circulates air throughout the chamber to promote homogeneous temperature distribution and maintain stable incubation conditions.
Combined with the adaptive multifunctional PID microprocessor controller and the Pt100 DIN Class A temperature sensor, the forced-air circulation system helps ensure accurate, stable, and uniform temperature control across the entire chamber.
DragLab uses forced-air circulation to maintain homogeneous temperature distribution throughout the chamber and to help keep the chamber temperature close to the selected setpoint, even when the incubator is fully loaded. This design supports reliable and reproducible incubation conditions across a wide range of laboratory applications.
Yes. The DragLab Incubator Series features an automatically adjustable forced-air circulation system with a quiet air turbine. During normal operation, the airflow is regulated automatically to promote homogeneous temperature distribution and maintain stable incubation conditions throughout the chamber.
The current product documentation does not indicate that manual airflow adjustment by the user is available. Airflow regulation is performed automatically by the incubator as part of its normal temperature control system.
Yes. The forced-air circulation system in the DragLab Incubator Series can affect the moisture content of samples during incubation.
The incubator uses an automatically adjustable forced-air circulation system to ensure homogeneous temperature distribution and maintain stable incubation conditions throughout the chamber. As the circulating air promotes efficient heat transfer, it can also increase moisture evaporation from exposed samples, particularly during long incubation periods or when working with uncovered containers.
For moisture-sensitive applications, samples should be placed in appropriately sealed or covered containers whenever required by the laboratory protocol.
The chamber of the DragLab Incubator Series is constructed from AISI 304 (EN 1.4301) stainless steel, providing excellent corrosion resistance, durability, and easy cleaning for routine laboratory applications.
The high-quality stainless-steel chamber is designed to withstand repeated laboratory use while supporting a clean and reliable incubation environment for research, clinical, pharmaceutical, food, and quality control laboratories.
Yes. The DragLab Incubator Series is equipped with an inner tempered safety glass door, allowing users to monitor samples without fully exposing the chamber to the external environment.
This design helps minimize heat loss and temperature fluctuations when the outer door is opened, supporting stable incubation conditions while enabling convenient observation of samples.
All DragLab Incubator Series models are supplied as standard with two chrome-plated wire shelves, providing flexible support for a wide variety of laboratory containers and samples.
Additional shelves can be installed to increase chamber capacity. The maximum number of shelves varies by model:
|
Model |
Standard Shelves |
Maximum Number of Shelves |
|
DI 30 / TI 30 |
2 |
5 |
|
DI 55 / TI 55 |
2 |
8 |
|
DI 80 / TI 80 |
2 |
10 |
|
DI 120 / TI 120 |
2 |
11 |
Additional wire shelves are available as optional accessories, allowing users to configure the chamber according to their application requirements. Each shelf has a maximum load capacity of 15 kg, ensuring reliable support for laboratory samples and containers.
Each shelf in the DragLab Incubator Series supports a maximum load of 15 kg.
The maximum permitted chamber load depends on the model:
- DI/TI 30: 75 kg
- DI/TI 55: 110 kg
- DI/TI 80: 150 kg
- DI/TI 120: 170 kg
Users should ensure that these load limits are not exceeded to maintain safe and reliable operation.
Each shelf in the DragLab Incubator Series supports a maximum load of 15 kg.
The maximum permitted chamber load depends on the model:
- DI/TI 30: 75 kg
- DI/TI 55: 110 kg
- DI/TI 80: 150 kg
- DI/TI 120: 170 kg
Users should ensure that these load limits are not exceeded to maintain safe and reliable operation.
The DragLab Incubator Series is designed with multiple safety features to support reliable, safe, and compliant laboratory operation. These include:
- Automatic thermostatic protection to help maintain stable operating conditions.
- Independent over-temperature safety device with an adjustable alarm limit for enhanced temperature protection.
- Audible alarm that can be enabled or disabled according to user preferences.
- Automatic diagnostic system for fault detection and troubleshooting.
- Automatic shutdown of the heating system and circulation fan when the door is opened, helping reduce heat loss and improve operational safety.
- Class I electrical equipment for electrical safety.
- IP20 protection class.
- Compliance with internationally recognized safety and EMC standards, including DIN 12880, EN 61010-1, EN 61010-2-010, EN 61326-1, and the applicable European Directives 2014/35/EU (Low Voltage Directive) and 2014/30/EU (Electromagnetic Compatibility Directive).
These integrated safety features help ensure dependable operation while protecting both laboratory personnel and valuable samples.
If an alarm appears on the display, first verify the incubator's operating conditions and ensure that it is being used within the specified operating limits. Check that the door is properly closed, the power supply is stable, and the temperature settings are appropriate for your application.
The DragLab Incubator Series features an automatic diagnostic system to assist with fault detection and analysis. If the alarm remains after correcting any obvious operating issues, discontinue use of the incubator and contact your authorized DragLab distributor or technical support for further assistance.
No. Flammable, explosive, or volatile substances must not be placed inside the DragLab Incubator Series. The incubator is designed for laboratory incubation applications and must not be used with materials that may produce flammable, explosive, or corrosive vapors.
To ensure safe operation, always use the incubator in accordance with the operating manual and laboratory safety procedures. Using incompatible materials may create a safety hazard and can damage the equipment.
The DragLab Incubator Series is intended for general laboratory incubation applications and must not be used with materials that generate flammable, explosive, or corrosive vapors.
When working with hazardous substances, users should ensure that the materials are compatible with the incubator and comply with all applicable laboratory safety procedures. Applications involving hazardous materials that may create a fire, explosion, or corrosion risk are not suitable for this incubator.
Check the spelling, try a different term or choose another category above. Or ask us directly: +49 6196 400816, info@drag-lab.de.
Planning a purchase?